Since I applied the correct defaults for version 4.66, I no longer get the warning beeps when I arm to night mode. How do I turn these back on. Regards ...
2
Lu Chiu
chiu@...
Jul 11, 2000 12:36 pm
According to our records (for 4.66), you should be getting arming beeps when you arm to night mode manually. Can you increase the Night Exit Time (Engineer...
3
Richard Lockyer
richard.lockyer@...
Jul 11, 2000 12:50 pm
The exit time is already at 10 seconds. When I key arm to night mode I get silence for ten seconds and then a beep and the "night mode" announcement. I used...
4
Andrew Roberts
andrew@...
Jul 12, 2000 12:31 am
Hi Richard, The groups have been quiet on technical issues. We are talking about marketing mainly and some development issues. We (UK) made a change to the...
5
Lyndsay Cotton
LCotton@...
Jul 12, 2000 12:27 pm
6
Andrew Roberts
andrew@...
Jul 12, 2000 1:13 pm
Lyndsay, 2 ways come to mind. 1. Enter Walk Test - F3,2 and deduce it from there by the announcement. or 2. Add output responses onto the door or gate zone so...
7
Lu Chiu
chiu@...
Jul 12, 2000 1:31 pm
To announce the status in the Home Control Menu,.. Connect the magnetic contact to an input. In every Control key in the Home Control Menu,you can specify an ...
8
Richard Lockyer
richard.lockyer@...
Jul 13, 2000 10:00 am
Thanks, That seems to have fixed it. Richard ... thought ... notepad, and ... screen, just ... still ... mode I ... the ... Night ... out ... forward ... ...
9
Lyndsay Cotton
LCotton@...
Jul 13, 2000 12:21 pm
Thanks for the reply's, but maybe I should re-phrase the question: Yes, if you want an answer locally then a visible signal, (such as a LED) would possibly...
Fit another contact to gate in open position preferably in the gate motor foundation box and programme as a seperate zone . Gerard...
12
Rod Stephens
rodsteph@...
Jul 15, 2000 12:48 am
I am encountering a very steep learning curve at the moment, having a partner with computer and technical skills depart the company scene. As a result, I have...
13
Lu Chiu
chiu@...
Jul 15, 2000 1:52 am
You have probably connected the PIR s to the S12V instead of the 12V terminals. S12V will automatically switch off for 5 seconds whever you disarm the system....
14
Andrew Roberts
andrew@...
Jul 15, 2000 8:33 am
Rod, It sounds like you have some wiring faults. Maybe even +ve supply shorted to a zone circuit, are you using staple guns on cable? 1st Golden Rule, always...
15
Rod Stephens
rodsteph@...
Jul 17, 2000 12:52 pm
Andrew We DO NOT USE STAPLES. IT IS VERBOTTEN FOR ANY OF MY CONTRACTORS. Anyway, thanks for the assistance, I think I can solve it from here. My next question...
16
Andrew Roberts
andrew@...
Jul 17, 2000 2:09 pm
It's sort of correct Rod. Comfort cannot facilitate phone to phone, but some DECT phones can do this already using radio channel. Or provided the phones are...
17
Harvey, Miles
mharvey@...
Jul 18, 2000 8:06 am
... which I could also use to notify me by phone-call that the power has been restored....
18
L.Y. Chiu
chiu@...
Jul 25, 2000 2:38 pm
Oops, we must have missed this question due to the recent proliferation of Comfort egroups. There is a Location 1847 which activates the programmed Response...
19
L.Y. Chiu
chiu@...
Jul 25, 2000 2:45 pm
To all who are testing the csxpress v3 beta. There is a new screen Memory Locations which can be used to program new Locations which are not handled in...
20
Andrew Roberts
andrew@...
Jul 25, 2000 2:46 pm
We have CSXpress 3.06 Available for download in the technical BETA area. http://www.comfort.org.uk/technical/ under 'BETA Software' Password Required CSX3...
21
Andrew Roberts
andrew@...
Jul 25, 2000 2:46 pm
We have CSXpress 3.06 Available for download in the technical BETA area. http://www.comfort.org.uk/technical/ under 'BETA Software' Password Required CSX3...
22
Harvey, Miles
mharvey@...
Jul 26, 2000 5:53 am
Hi, Unfortunately I'm running 4.59, any other ideas. Thanx Miles ... From: L.Y. Chiu [mailto:chiu@...] Sent: 25 July 2000 16:38 To:...
23
L.Y. Chiu
chiu@...
Jul 26, 2000 5:58 am
The easiest solution is to upgrade to a later version We do not have an alarm restore Response, so the special location is the only way to do it chiu ... when ...
24
Rod Stephens
rodsteph@...
Jul 26, 2000 12:33 pm
Andrew I now have a new programmer who is doing wonders with his Comfort. I do not know if you are aware, but he has discovered that an X-10 flood sends out 1 ...
25
Andrew Roberts
andrew@...
Jul 27, 2000 12:53 am
Dear All, We have updated some Manuals in the Technical Area and also the Light Sensor Manual (LSM01)in the Products Area....
26
Andrew Roberts
andrew@...
Jul 28, 2000 12:25 am
Very innovative Rod, what am I going to do with all these LSM01's now? -:)) (light sensor modules) http://www.comfort.org.uk/products/lsm01.html You didn't...
27
Nigel Orr
comfort@...
Aug 3, 2000 1:43 pm
I know there are some default codes supplied in the comfort .csx file. Are these also in the EEPROM by default, or do they have to be put there by a CSX...
29
L.Y. Chiu
chiu@...
Aug 3, 2000 1:53 pm
Looking at the UK default csx file, Code 1 is Sony TV ON and Code 2 is Sony TV off. These should be in your U4 EEPROM so you can try it if you happen to have a...
30
Nigel Orr
comfort@...
Aug 11, 2000 11:53 am
I have Comfort set up so it can mute the audio in the house. I'd like to use it to turn off the sound when a phone call is in progress. I know that Comfort...
31
L.Y. Chiu
chiu@...
Aug 11, 2000 12:02 pm
Nigel Comfort can detect when the local phone is taken offhook and replaced onhook, but we have not associated any responses with these events. This can be...