101 Frans Rampen
Frans@... Send Email
Nov 1, 2000
2:01 pm
Hello dear comfort users, I have a question about the recording time of the answering machine. Since I have upgraded my system with the CWI (and thus also the ...
102 L.Y. Chiu
chiu@... Send Email
Nov 1, 2000
2:11 pm
In this version, we removed the individual recording time settings for the different message types. Greeting message, incoming messages, Alarm Messages, User...
103 adrian.lucas@... Send Email Nov 1, 2000
2:41 pm
Thanks Adrian, yes it is now available after firmware version M4.83, it is listed as location 1847. (Power Fail Restore Response) Andrew CHC After the recent...
104 Andrew Roberts
andrew@... Send Email
Nov 1, 2000
7:33 pm
If you have UCM01, please visit the following page and download the latest version of Comfort programming software. Download file is in zip format and is about...
105 Andrew Roberts
andrew@... Send Email
Nov 5, 2000
3:24 pm
X10 Products and UCM are now in stock! If you have been waiting for our X10 product stocks to get back to normal and for the UCM (RS232 Module) to arrive in...
106 comfort@... Send Email Nov 7, 2000
1:41 pm
I was searching through the worksheets for somewhere I could program a response code to be activated upon successful arming, e.g. to switch off all downstairs...
107 L.Y. Chiu
chiu@... Send Email
Nov 7, 2000
1:47 pm
You have missed Table 30 - Security Mode Responses. You can program a Response to be activated when the system is armed to Away,Night, Day,or disarmed to Off ...
108 comfort@... Send Email Nov 7, 2000
10:47 pm
Andrew, You will notice that there are already some responses in the Security Mode Responses positions, this is intentional, it is best to add your new...
109 Andrew Roberts
andrew@... Send Email
Nov 10, 2000
9:46 am
Just to let you know, the Comfort website at www.comfort.org.uk is temporarily down while domains are being shifted and will be up and running again later...
110 Andrew Roberts
andrew@... Send Email
Nov 10, 2000
10:43 am
Dear All, The Comfort website is now back on-line: http://www.comfort.org.uk However, the following domains are being transferred and may not work for a few...
111 John Parker
john@... Send Email
Nov 13, 2000
7:42 pm
Hi all I'm having a problem with the doorphone on my Comfort system. Firmware is "Outside 4.93". There is a PIR+Camera by the door in question. The Camera...
112 L Y Chiu
chiu@... Send Email
Nov 14, 2000
1:16 am
Do you mean that the PIR is detecting movement when the doorbell is pressed? When the announcement is being made on the keypads, and the doorbell is pressed,...
113 Andrew Roberts
andrew@... Send Email
Nov 14, 2000
1:31 am
John Another idea that I've used before to defeat the announcements, is to start a timer for 3 mins (say timer 16) triggered from the Doorbell Button, in ...
114 comfort@... Send Email Nov 14, 2000
9:12 am
I have noticed that some locations covered in Table 10 (actually, all of the few I've checked) have 128 added to them. This isn't described in the worksheet...
115 L Y Chiu
chiu@... Send Email
Nov 14, 2000
12:48 pm
There is some inconsistency between the worksheet and the default settings. The value 128 (Bit 7) is not used at present so it has no effect on the zone type ...
116 Lyndsay Cotton
LCotton@... Send Email
Nov 23, 2000
10:31 am
Hello Lyndsay, I have never come across this symptom, Comfort has no adjustment for the doorphone time, I suspect there could be a loading or interference...
117 Lyndsay Cotton
LCotton@... Send Email
Nov 23, 2000
12:49 pm
Thanks Andrew - will try it out I can confirm that it has worked fine until recently - installed in Jan 2k This is not my panel but one I did for a colleague...
118 Andrew Roberts
andrew@... Send Email
Nov 23, 2000
1:12 pm
Thanks Lyndsay, From a diagnostic pint of view , it helps to provide as much background information as possible in the first instance so we can narrow down the...
119 Lyndsay Cotton
LCotton@... Send Email
Nov 23, 2000
9:19 pm
... From: Geoff Zeiler [mailto:gzeiler@...] Sent: 23 November, 2000 2:23 PM To: LCotton@... Subject: RE: [comfort-technical] Re: doorphone...
120 Andrew Roberts
andrew@... Send Email
Nov 25, 2000
1:51 pm
We have updated and re-organised the help pages for Comfort Web Interface and CsxXpress3. Make sure you refresh your browser when you get there to flush on the...
121 Andrew Roberts
andrew@... Send Email
Nov 26, 2000
2:54 pm
Dear All, We have added some new technical manuals and updated the existing ones: http://www.comfort.org.uk/technical/ (password required) Including a new...
122 Lyndsay Cotton
LCotton@... Send Email
Nov 29, 2000
8:59 am
I have an installation (actually the 3rd already) where the client stays in a small cluster complex. The complex has each unit linked to the main gate via a...
123 Andrew Roberts
andrew@... Send Email
Nov 29, 2000
11:08 am
Lyndsay, We are working on a Central Doorphone (CDP01)for Comfort providing a single doorphone to link with hundreds of Comfort systems locally. The...
124 nigel@... Send Email Nov 29, 2000
8:20 pm
I've recently upgraded to "outside 4.102", and made some programming changes, not sure if the upgrade is relevant... My system previously armed automatically...
125 Andrew Roberts
andrew@... Send Email
Nov 29, 2000
8:35 pm
Nigel, Have you started using CSX3 to download now, it may be something to do with the 'night arm' siren type. Our defaults have been set to 'No Siren' for...
126 Richard leslie
r.leslie@... Send Email
Nov 30, 2000
3:27 pm
Andrews, After my recent comfort Install , comprising of 5 Kompads ,and numerous detectors /cameras Some of the terminals on comfort PCB ,could do with a cable...
127 A R
andrew@... Send Email
Nov 30, 2000
3:31 pm
Richard, I know exactly what you mean, I've been there too. I know that the PCB will not allow any more block or spaces etc, maybe we could consider a piggy...
128 nigel@... Send Email Nov 30, 2000
9:59 pm
... I've brought most of my Comfort connections out to Krone terminals, it's a very reliable system, and easy to connect multiple wires together (for 12V etc)....
129 L Y Chiu
chiu@... Send Email
Dec 1, 2000
6:22 am
... You have not made any mistakes. With the new version, we added back the beeping tones on auto-arming. It used to be this way but we took out the beeping on...
130 Lyndsay Cotton
LCotton@... Send Email
Dec 1, 2000
9:14 am
Couldn't agree more, As mentioned a few months ago, I create a harness terminating in a "chocolate block" strip - and feed the outputs/inputs from there. This...