Gary, I've run the video for the video doorphone over SHIELDED 8 core alarm cable - works OK but there is a slight loss in quality of the picture. I suspect...
what is the best way to implement a settle timer on the comfort. the scenario is the pir in the hallway continues to be open after the final door exit time has...
Gary, You can send video over cat 5 cable using what is called a video balun. You will need 2, one at each end. They are available from Channel Vision....
... know ... I've used 6 & 8 core bt cable (i.e. not twisted pair or screened) and it was fine for runs up to 30metres, as long as you don't run it next to...
i have upgraded to 2 doorstations with camras i want to be able to switch to the doorstation camera that the button was pressed on does anyboby have any ideas...
Nick, using a response on the doorbell button which checks the Doorphone ID (73,18) before choosing Cam 1 or 2 will work. 49 is DP1/Cam1 and 50 is DP2/Cam2 eg:...
I've been getting a few people pressing the doorbell when I'm out recently. Comfort dials to my mobile OK but if I miss that it goes to my voicemail....
... No neither did I. Thankfully my supplier questioned it once he found out how much it was for me. ... All mains cables are run around 300mm from data cables...
Currently I send cctv round house using the cat 5. For black and white it and short colour runs, it doesn't seem to be a problem. I use the following ...
Hi, Can the exit terminate tab be applied via dial up, or is it only set via local connection by UCM It will save me a lot of time and travelling if it can be...
When you arm to away mode remotely, exit terminator does not apply, as Comfort knows you are not at home. The system will arm after the exit time. chiu ... ...
There is no way to increase the announcement or repetition time during the dialout, but if you record an alarm message (Program Menu 3,5), this will be played...
You can temporarily bypass the PIR, activating this from the Start Arming Response (Events > Misc Responses). Unbypass the zone when the system is armed (Alarm...
Many thanks Chiu But the query was regarding implementing the ET, I had recently visited the customers premises and somehow the ET tab had become 'un-ticked'...
Terry, location 1692=2 determines Exit Terminator and can be set/checked remotely regs Andrew Roberts Comfort Home Controls - UK (Tel: 44(0)1244 680675) (Fax:...
Hello People, The following code is not working , only the comand X10 B6 Off is made. The idea is after send the X10 code A15On Execute the Response nr 231 ...
Hi Jose, Could you please paste the action codes from all of these responses into the email? this can reveal more than just the CF code. The actions are found...
thanks, ill try that. there is no settle time on the pirs, and they do seem to stay open for an unusually long time. However on some dual techs as standard on...
The problem with R231 is after the B6 Off command, you start a timer for 30 seconds then immediately check the F04 flag. F04 Flag will always be 0 because the...
Thanks to everyone who replied about KAT5 and using regular wiring for CCTV. You've encouraged me to try normal wiring first and then if I'm not happy with...
An explanation of how the X10 and output commands work is needed. When you perform a series of X10 and output commands, they are sent to a queue to wait their...
Hi, I had connected the UWM to the PC accordingly, the led lights (red and Green) are blinking. However, I am not able to run the Telnet. What should I do to...
... Do you mean UCM or CWM? There is no UWM. ... Did you record the reminder on the keypad or telephone? Try it on both and use the Pay Reminder message option...
For video over cat5, see http://www.kat5.tv/ .. it's the cheapest i've seen. ... know ... so ... <cytech_tech@y...> ... your ... Slave ... am ... video...
Can this be logged as a future enhancement? Wouldn't it be great to have some control over the whole dial out process e.g. how many times should the message...