4529 mike
vtr2t Offline Send Email
Aug 1, 2004
11:56 am
Thanks Chiu Any idea where the comfort.xml file can be found? Thanks in Advance Mike _____ From: L Y Chiu [mailto:cytech_tech@...] Sent: 01 August 2004...
4530 davidalucas Offline Send Email Aug 1, 2004
11:56 am
Hi, Can anybody give me a clue how I can write something for Comfort within configurator so that when the light sensor detects it is dark, when arming the...
4531 Comfort Home Controls
alpisc Offline Send Email
Aug 1, 2004
11:58 am
David Currently the Siren Type initiates the Away Mode Siren and there is not way to conditionalise them. So you will need to remove the Siren Type Away/Armed ...
4532 L Y Chiu
cytech_tech Offline Send Email
Aug 1, 2004
1:30 pm
I would have sent the file, but I dont have it at home. I will upload it to the website tomorrow chiu ... ===== Cytech Technology Pte Ltd 55 Ubi Ave 1 #07-04,...
4533 davidalucas Offline Send Email Aug 1, 2004
3:47 pm
Hi Andy, Thank you for the reply. 1 Could I rename the siren type 'AwayArmed' so inturn the system would not be able to action it as it could not find it. ...
4534 Comfort Home Controls
alpisc Offline Send Email
Aug 1, 2004
3:49 pm
Siren Types do not activate responses so any adjustment as you describe is futile, I must refer you back to my original answer. Best Regards Andrew Roberts ...
4535 mike
vtr2t Offline Send Email
Aug 2, 2004
1:23 pm
Thanks Chiu I would appreciate that Mike _____ From: L Y Chiu [mailto:cytech_tech@...] Sent: 01 August 2004 14:30 To: comfort-technical@yahoogroups.com ...
4536 Mike Griffiths
vtr2t Offline Send Email
Aug 2, 2004
8:02 pm
I would like to set up some switches on Cbus that can be detected by comfort I think I understand the system of Counters getting the Lighting Control levels...
4537 L Y Chiu
cytech_tech Offline Send Email
Aug 3, 2004
12:48 am
Mike The sample Comfort configuration files for C-Touch have been posted on the website www.cytech.biz/software.hmtl Unzip the file into the C-Touch folder. It...
4538 mike
vtr2t Offline Send Email
Aug 4, 2004
12:34 am
Thanks Chiu I shall have a play mike _____ From: L Y Chiu [mailto:cytech_tech@...] Sent: 03 August 2004 01:49 To: comfort-technical@yahoogroups.com ...
4539 tedvpt Offline Send Email Aug 4, 2004
12:35 am
Hello, I've just installed a comfort pro in my house and I would like to say it is the business so far. I have all 8 zone used and I will be purchasing the...
4540 L Y Chiu
cytech_tech Offline Send Email
Aug 4, 2004
8:23 am
The comms failure 49 is strictly due to the absence of a door station. The green led flashes because of the Communications failure. This indicates a trouble...
4541 Rob Kirkbride
comfort@... Send Email
Aug 4, 2004
9:13 am
Hi, Can someone remind me how to get in engineer mode - I've forgotten! I've got the code but an electrician is coming this morning, and I want to stop it...
4542 L Y Chiu
cytech_tech Offline Send Email
Aug 4, 2004
9:24 am
Press F0 and 6789# will get you in chiu ... want...
4543 Geoff Zeiler
geoffzeiler Offline Send Email
Aug 4, 2004
10:12 am
Hi, Push "F0" on the keypad, than sign in with the eng number. Regards, Geoff ... Hi, Can someone remind me how to get in engineer mode - I've forgotten! I've...
4544 Ted O'Riordan
tedvpt Offline Send Email
Aug 4, 2004
2:21 pm
Chiu, Many thanks for the swift reply. Just to confirm your answer, will I always get a "comms failure 49" because I don't have a door station? I don't plan...
4545 L Y Chiu
cytech_tech Offline Send Email
Aug 4, 2004
2:30 pm
... 49" because ... station in the ... You can set No of Door stations to 0 on Comfigurator, or if you dont use the software, set Location 1674 to 0 on the...
4546 Ted O'Riordan
tedvpt Offline Send Email
Aug 5, 2004
12:26 am
Thanks again Chiu, I will implement all of your suggestions. Thanks again. Ted P.S Do you ever sleep? ... From: L Y Chiu [mailto:cytech_tech@...] Sent:...
4547 L Y Chiu
cytech_tech Offline Send Email
Aug 8, 2004
8:39 am
We have just found that when doing a Voice Download from Comfigurator, any change in state of zone/input, or an alarm activation, which causes a broadcast...
4548 Tony Sexton
tonenmarce Offline Send Email
Aug 8, 2004
10:49 pm
Hi All, I have had trouble for a while now in controlling my X10 modules from comfort (and also homeseer), sometimes commands don't work at all and other times...
4549 flidgetuk2002 Offline Send Email Aug 8, 2004
10:51 pm
We are going to move to ADSL Broadband. All the PSTN equipment needs a filter. Can anyone tell me what is required for the Comfort connection. Currently we...
4550 L Y Chiu
cytech_tech Offline Send Email
Aug 9, 2004
2:11 am
Although the 1 MHz ADSL frequencies should go through Comfort from TEL IN to TEL OUT, it is best to place the ADSL Modem before Comfort, ie in parallel to ...
4551 L Y Chiu
cytech_tech Offline Send Email
Aug 9, 2004
2:14 am
The led flashes when there is outgoing and incoming X10 activity. Try diconnecting each X10 module which is capable of sending signals one by one to see if any...
4552 elvatron2 Offline Send Email Aug 12, 2004
10:32 pm
Hi, I try to connect my computer to the Web server. When I run the CwmSetup.exe the program dont show me the IP address of the Web Server Module. Could you...
4553 L Y Chiu
cytech_tech Offline Send Email
Aug 13, 2004
12:58 am
If you connect your computer directly to the CWM (instead of through a hub), make sure you use a crossed CAT5 cable. If you connect the cable to the CWM after...
4554 lawrert Offline Send Email Aug 15, 2004
6:10 pm
Have made a slight change to my config file on Comfigurator. Have not used comfigurator for a while. Error message says that vocab is different ? Does this...
4555 keith_emma Offline Send Email Aug 16, 2004
1:04 am
Hi, I can arm my system to away mode remotely from a cell phone. When I try to do the same from the Keypad the system prompts you to leave , announces away...
4556 L Y Chiu
cytech_tech Offline Send Email
Aug 16, 2004
1:08 am
Comfigurator 1.5.0 has a new vocabulary management scheme which keeps the vocabulary system information in the Nonvolatile memory in 2 locations. If you have...
4557 L Y Chiu
cytech_tech Offline Send Email
Aug 16, 2004
1:14 am
When arming to Away Mode locally from a keypad, the system announces "please exit" if all monitored zones are closed. When you go out of the house and close ...
4558 keith_emma Offline Send Email Aug 16, 2004
8:09 am
... "please ... house and close ... 2 blasts ... determiend by ... Siren Type 5 to ... beeping on the keypad and speaker.What concerns me is that I cannot arm...