456 emyrgeorge@... Send Email May 2, 2001
4:06 am
Since I use a 10 sec timer frequently, I was hoping to make a response for it as follows:- xxx 74,166 (Do 166) 166 194,1,0,10,167,255 167 255. Unfortunately...
457 Andrew Roberts - Comf...
andrew@... Send Email
May 2, 2001
7:59 am
... Emyr, It looks like you need to put some function into R167 because, when R166 operates it then does R167 after 10 secs which has nothing in the line ...
458 Geoff Zeiler
gzeiler@... Send Email
May 2, 2001
12:22 pm
Hi Chui, This problem only concerns the text in the "comments" tab of "general info". The first 2 lines in comments seem to save, but from there on it is...
459 L Y Chiu
chiu@... Send Email
May 2, 2001
1:19 pm
Thanks for the detailed info. We are lookiong into it and should have an update soon chiu ... ===== Cytech Technology Pte Ltd 55 Ubi Ave 1 #04-06, Singapore...
460 L Y Chiu
chiu@... Send Email
May 2, 2001
1:33 pm
The timer actually would work but you do not know it because the target response at the end of the timer does nothing, ie it is empty If you are using it like...
461 L Y Chiu
chiu@... Send Email
May 3, 2001
11:33 am
Mr Savides Your correction is OK. I can verify that it does not announce the name of the person who announced. That is because the system announces the name of...
462 Marinos Savvides
marinossavvides@... Send Email
May 3, 2001
3:15 pm
Hi, You are right, I know that when I get a "Home Safe Sign In report" it is because User 2 has disarmed the system, so the name is not essential anyway. ...
463 nigel@... Send Email May 4, 2001
7:58 am
Hi I am thinking of controling some of my lights with Comfort, should I use X10 Din controlers or should I use 240V rated Relays attached to Comforts outputs ?...
464 Andrew Roberts - Comf...
andrew@... Send Email
May 4, 2001
8:15 am
... The LD11 X10 DIN Unit is better because you also have the ability to DIM, Brighten and Pre-set Dim, relays will have no such function. Additionally, the...
465 Mark McCall
mark@... Send Email
May 4, 2001
9:31 am
Nigel You should use X10 Din rail module (LD11) for your lights as this will give you dimming. Other circuits (heating control for example) might be better ...
466 Jonathon Greiff
jgreiff@... Send Email
May 4, 2001
1:34 pm
I am about to install new central heating system. Does anyboy know if there is a Central Heating Make for which the Comfort System can communicate with and has...
467 Matt Pavall
mp_egroups@... Send Email
May 8, 2001
10:45 am
... of ... check. ... 72, the 71 arms without providing the exit requirement, ... Andrew, I didn't see your reply first, it got wrapped up into my original...
468 L Y Chiu
chiu@... Send Email
May 8, 2001
4:31 pm
Matt If you dial in remotely and press 1,1 to arm to away mode, you should get security check. If there are any zones open they will be announced. You can...
469 patrickl@... Send Email May 8, 2001
7:48 pm
I posted a message a while ago about my problems with distortion present on phone lines using Comfort with Homehighway. I'm not making much headway. To recap: ...
470 Matt Pavall
mp_egroups@... Send Email
May 9, 2001
12:15 am
Chiu, Yes, I want to arm to away mode with security check, just like dialling in and pressing 1,1 - but as a response to an input circuit closing instead. I...
471 L Y Chiu
chiu@... Send Email
May 9, 2001
1:04 am
Matt What I dont understand is how you will know what zones are open in security check if you have already left the house? Action 71 is for auto-arming which...
472 L Y Chiu
chiu@... Send Email
May 9, 2001
1:52 am
What is Home Highway, is it an ISDN line? The connection from TEL IN to TEL OUT on Comfort is straight through, there is no amplification or attenuation. There...
473 Ian Clarke
ian.clarke@... Send Email
May 9, 2001
4:11 am
Hello, can anyone help me in obtaining the .ifr file for a SONY VCR. The infrared.cfg file delivered with CS-Xpress 3.18 has an entry for a "generic" SONY VCR...
474 chiu@... Send Email May 9, 2001
5:53 am
Ian Have you tried using the Pronto conversion utility which is distributed within CSXpress as infared.exe. This allows you to convert any IR file learned by...
475 joe.lorenz@... Send Email May 9, 2001
6:05 am
I am sorry to hear about the current difficulty your are having and Pinpointing the problem can be a long-pain staking process. I will provide my expert ;-)...
476 L Y Chiu
chiu@... Send Email
May 9, 2001
6:25 am
Geoff Use action 24 to echo all voice on the keypad. Program a response with just action 24 and assign it to a keypad function key (I usually use *) Then press...
477 Matt Pavall
mp_egroups@... Send Email
May 9, 2001
7:54 am
Chiu, The main reason for wanting the security check is to let any zones still activate from movement in the house to settle down instead of getting bypassed....
478 Mark McCall
mark@... Send Email
May 9, 2001
7:56 am
... Chiu I have a dodgy back door conntact and often need to by-pass it when arming. I have just tried pressing 3 to force arm (without first by-passing the...
479 L Y Chiu
chiu@... Send Email
May 9, 2001
8:37 am
Mark You mean you press # for Force arm not 3?. You system may be set to disable Force arm in Engineer Menu 4,3,1 (off) This prevents force arming. If your...
480 Mark McCall
mark@... Send Email
May 9, 2001
10:05 am
I use # when I'm home but I thought you were saying I could use 3 over the phone to force are? Can I force arm over the phone without having to go into the...
481 L Y Chiu
chiu@... Send Email
May 9, 2001
10:18 am
Mark yes you can also use # to force arm over the phone when you hear that zones are open To abort the arming, press * The difference with Bypass is that the...
482 Mark McCall
mark@... Send Email
May 9, 2001
10:42 am
Just tried this over the phone Chiu. When I get the "Back Door" announcment I hit the # key - but all I get then is "Security OFF" ??? M. Mark, have you...
483 L Y Chiu
chiu@... Send Email
May 9, 2001
1:10 pm
Mark yes that's right, that means your Force arm option is set to Off (in Engineer menu 4,3,1) which prevents you from force-arming the system chiu ... ===...
484 patrickl@... Send Email May 10, 2001
12:42 am
... Yes ... Comfort does not work with the analogue port on HH and never has. It does work using the digital port an external terminal adapter. ... still ... ...
485 patrickl@... Send Email May 10, 2001
12:42 am
... Home Highway is ISDN 2e delivered to a telco-owned analogue terminal adapter which provides 2 POTs interfaces (standard analogue ports) each with a...