OOOPs. Yes I suppose I do Wayne. At least the data sheet would have corrected that bit. To Others the 78 series regulators are positive voltage regulators. The...
Hello, Is it Feb 1 yet? ... From: "Mariss Freimanis" <mariss92705@...> To: <geckodrive@yahoogroups.com> Sent: Tuesday, January 23, 2007 5:02 PM Subject:...
Yes In too much of a rush today, I am always dyslectic with the keyboard. Just bought my first pick n place machine, telephone gone nut's, order book gone...
Do all the stepper drives contain the morphing microstep to full step feature , or is that exclusive to the 203V? Thanks Eric ... for ... into a ... out ... ...
Oh I see...so there *are* "free lunches" out there, but they only come in a lunchbox marked Geckodrive? I guess its important to have an exception to every...
Yes. Chateau Geckeau serves free lunch daily, 8AM thru 5PM, Monday thru Friday. The lunch menu is a delicately crisped FR-4 spread with a savory melted SnCuAg...
Sorry, that's slightly ambiguous... among the 201,202 and 203 series, which have the morphing feature? ... used ... revs/sec ... channel ... frequencies ... ...
I have a bunch of mid 90's servo motors and drives (mainly yaskawa cacr series) that I would like to use in a retrofit. How can I tell if I can use those with...
But that would be the neg side of the cap. I was talking about 115v ground and I think your talking about the neg side of the secondary of the power supply? ...
Hi there, I have just started playing with a G100 motion controller and I now have a few question I am sure someone will be able to help me with. Question 1 As...
OK :-), my 3 are on the way to oHIo either way.........yayyyyyyyyyyyyy Bill ... From: Mariss Freimanis To: geckodrive@yahoogroups.com Sent: Thursday, February...
Don, On my systems I only ground the green wire. My AC line (black and white wires) all go to the primary windings of transformers. Robert Colin Campbell Bob...
But does that mean both should be grounded? Power company ground and secondary of tranformer after rectifier -? Thanks for the responce Donald Clifton ... ...
Never got an anwser to my question. Shouls you ground the back plane to electrical (power company) ground? and of course power supply ground? Thanks Don ... ...
Don, The secondary of the power transformer in my case is the input to my bridge rectifier. The secondary of the transformer is not grounded. After the...
The input to the bridge rectifier is still a/c. I like you have my green wire from A/C power source grounded to the back plane and I know that through the...
Don, I would think that this is standard practice. I always take the green wire and wire it to the chassis ground. Then the negative side of the power supply...
Thanks, I was just wondering, Don ... From: geckodrive@yahoogroups.com [mailto:geckodrive@yahoogroups.com]On Behalf Of Bob Campbell Sent: Thursday, February...
jean-claude charlier, No, I am buying my motors from a different supplier. Robert Colin Campbell Bob Campbell Designs www.Campbelldesigns.net Mach 2/3 breakout...
... I'm going to totally disagree with others on this forum about grounding procedures. I always ground chassis components to AC ground (NOT AC neutral)....
Wrong. The negative side of the motor DC power supply connects to the chassis! Your PC power supply ground (black wires) connect to the PC chassis, your...
I replaced all the drive belts on my servomill disturbing most of the encoder and shaft connections. When I went to power the mill back up the X Gecko LED...